Transcutaneous Bilirubin Measurement in Preterm Neonates
Abstract
Hyperbilirubinemia is a common problem during neonatal period especially in preterm neonates. Transcutaneous bilirubin measurement (TcB) by special devices had been documented as an effective tool for predicting neonatal jaundice in full term neonate, but for preterm infants the present evidences are controversial. We carried out a prospective study in Shariati Hospital NICU. 126 paired TcB/total serum bilirubin (TSB) measurements were obtained. TcB (on forehead and sternum) were measured using JH2-1A device for every admitted preterm infant who clinically showed jaundice and TSB measurements was obtained within 30 min of TcB. 58 (46%) were male and 68 (54%) were female. The mean gestational age was 31 week and mean birth weight was 1728 ± 60 g. 30 percent of neonates were ill. The mean value obtained by TBS was 8.8 mg/dl and for frontal TcB was 8.2mg/dl and for sternal TcB was 7.4mg/dl. There were good correlation between TBS and TcB and the maximum correlation were seen in 33-37 weeks of gestation and birth weight more than 2500 g with forehead TcB measurement. Healthy preterm infants had significant correlation of TSB and TcB (r=0.56, P<0.001) and ill preterm neonate had r =0.82, P<0.001. The correlation between TBS and TcB with and without phototherapy was r=0.66, P=0.000 and r=0.69, P=0.000 respectively. Although TcB measurement may underestimate TBS but there is significant correlation between TcB and TBS in preterm cases even in ill neonate or who receiving phototherapy. This method can be used for determination of bilirbin level in preterm neonate and reduces the number of blood sampling.
Amato M, Huppi P, Markus D. Assessment of neonatal jaundice in low birth weight infants comparing transcutaneous, capillary and arterial bilirubin levels. Eur J Pediatr 1990; 150(1):59-61.
Bhutani VK, Gourley GR, Adler S, Kreamer B, Dalin C,Johnson LH. Noninvasive measurement of total serum bilirubin in a multiracial predischarge Newborn population to assess the risk of severe hyperbilirubinemia. Pediatrics 2000; 106(2):E17.
De Luca D, Zecca E, de Turris P, Barbato G, Marras M,Romagnoli C. Using Bilichecktfor preterm neonates in a sub intensive unit: diagnostic usefulness and suitability. Early Hum Develop 2007; 83(5):313-7.
Donzelli G, Pratesi S. Transcutaneous bilirubinometry in healthy preterm newborns. Clin Biochem 2000; 33(6):505-8.
Ebbesen F, Rasmussen LM, Wimberley PD. A new transcutaneous bilirubinometer,Bilicheck, used in the neonatal intensive care unit and the maternity ward. Acta Paediatrics 2002; 91(2):203-11.
Engle WD, Jackson GL, Stehel EK, Sendelbach DM, Manning MD. Evaluation of a Transcutaneous jaundice meter following hospital discharge in term and near-term neonates. J Perinatol 2005; 25(7):486-90.
Ghafari SV, Vahid Shahi K. Evaluation of transcutaneous bilirubinometry in ill patients. Scientific Journal ofMazandaran Medical University 2003; 40:43-50.
Jangaard K, Curtis H, Gold Bloom RB. Estimation of bilirubin using bilicheck, a transcutaneous bilicheck: effect of gestational age and use of phototherapy. Paediatr Child Health 2006; 11(2):79-83.
Kaplan M, Wong RJ, Sibley E Neonatal jaundice and liver disease in Martin RJ, Fanaroff AA, Walsh MC. Neonatal and perinatal medicine. Elsevier 2011: 1443-96.
Karolyi L, Pohlandt F, Muche R, Franz AR, Mihatsch WA. Transcutaneous bilirubinometry in very low birth weightinfants. Acta Paediatr 2004; 93(7):941-4.
Kazmierczak SC, Robertson AF, Briley KP, Kreamer B,Gourley GR. Transcutaneous measurement of bilirubin in newborns: comparison with an automated Jendrassik- Grofprocedure and HPLC. Clin Chem 2004; 50(2):433-5.
Knüpfer M, Pulzer F, Braun L, Heilmann A, Robel-Tillig E, Vogtmann C. Transcutaneous Bilirubinometry in preterm infants. Acta Paediatr 2001; 90(8):899-903.
Nanjundaswamy S, Petrova A, Mehtar R, Bernstein W, Hegyi T. Accuracy of transcutaneous bilirubin in neonate: a correlation study. Neonatology 2004; 85(1):21-5.
Maisie’s MJ. Historical perspective: transcutaneous bilirubimetry. Neo Reviews 2006; 7(7):e217–25.
Maisels MJ, Ostrea EM Jr, Touch S, Clune SE, Cepeda E, Kring E, Gracey K, Jackson C, Talbot D, Huang R. Evaluation of a new transcutaneous bilirubinometer. Pediatrics 2004; 113(6):1628-35.
Namba F, Kitajima H. Utility of a new transcutaneous jaundice device with two Optical paths in premature infants. Pediatr Int 2007; 49(4):497-501.
Nanjundaswamy S, Petrova A, Mehta R. Transcutaneous bilirubinometry in preterm infants receiving phototherapy. Am J Perinatology 2005; 22(3):127-31.
Rubaltelli FF, Gourley GR, Loskamp N, Modi N, Roth- Kleiner M, Sender A, Vert P. Transcutaneous bilirubin measurement: a multicenter evaluation of a new device. Pediatrics 2001; 107(6):1264-71.
Sanpavat S, Nuchprayoon I. Transcutaneous bilirubin in the pre-term infants. Journal of the Medical Assosiation of Thailand 2007; 90(9):1803-8.
Schmidt ET, Wheeler CA, Jackson GL, Engle WD. Evaluation of transcutaneous bilirubinometry in preterm neonates. Journal of Perinatalogy 2009; 29(8):564-9. 21. Stillova L, Matasova K, Mikitova T, Stilla J, Kolarovszka H, Zibolen M. Evaluationof transcutaneous bilirubinometry in preterm infants of gestational age 32-34 weeks. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2007; 151(2):267-71.
Willems WA, van den Berg LM, de Wit H, Molendijk A. Transcutaneous bilirubinometry with the Bilicheckt in verypremature Newborns. Maternal-Fetal Neonatal Med 2004; 16(4):209-14.
Wong CM, Van Dijik PJE, Laing IA. A comparison of Transcutaneous bilirubinometers: Spect Rx Bili Check versus Minolta Air Shields. Arch Dis Child Fetal Neonatal Ed 2003; 87(2):137-40.
Yasuda S, Itoh S, Isobe K, Yonetani M, Nakamura H, Nakamura M, Yamauchi Y, Yamanishi A. New transcutaneous jaundice device with two optical paths. J Perinat Med 2003; 31(1):81-8.
Files | ||
Issue | Vol 50, No 11 (2012) | |
Section | Original Article(s) | |
Keywords | ||
Jaundice Preterm Total serum bilirubin Transcutaneous bilirubin measurements |
Rights and permissions | |
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. |