Original Articles

Comparison of aPTT and CT Parameter of the ROTEM Test to Monitor Heparin Anti-Coagulation Effect in ICU Patients: an Observational Study

Abstract

Heparin is frequently used in different clinical settings to reduce the coagulating ability of the blood. Because of probable adverse effects owing to heparin therapy and regarding variability of patients’ responses to heparin, which make it very unreliable, it seems prudent to monitor meticulously its effects on the human body. There are a lot of laboratory tests to watch its effects on the body for example; aPTT and ROTEM are the most widely used tests that are performed today. We aimed to compare the aPTT test results against changes of CT parameter of the ROTEM test due to heparin administration. This study was conducted on 45 critically ill patients who needed to receive heparin according to their clinical status. All patients received 550 to 1500 unit heparin per hour (on average 17.5 unit heparin per kilogram weight). While the patients were under infusion of heparin, two blood samples (5 ml) were taken from a newly established cubital vein, just five hours after commencement of heparin therapy. One sample was used for aPTT and the other one for ROTEM. The correlation between aPTT and the changes of CT parameter of the ROTEM with heparin dosage and infusion was the primary outcome. The correlation between heparin therapy and the changes of other parameters like MCF, CFT, and a number of platelets were the secondary outcome of the study. The only significant correlation was between changes of CT and aPTT (P=0.000). The other variables were not correlated. Changes of CT parameter of ROTEM test can be used for monitoring of reduced coagulability during heparin infusion instead of aPTT test.

Katzung BG, Mastres SB, Trevor AJ, editors. Basic and clinical pharmacology. 12th ed. New York, NY: McGraw- Hill; 2012: p. 601-19.

Levya JH, Faraonib D, Sniecinskia RM. Perioperative coagulation management in the intensive care unit. Curr Opin Anaesthesiol 2013;26(1):66-70.

Mittermayr M, Margreiter J, Velik-Salchner C, et al. Effects of protamine and heparin can be detected and easily differentiated by modified thrombelastography (Rotem): an in vitro study. Br J Anaesth 2005;95(3):310-6.

Gertler R, Wiesner G, Tassani-Prell P, et al. Are the Pointof- Care Diagnostics MULTIPLATE and ROTEM Valid in the Setting of High Concentrations of Heparin and Its Reversal with Protamine? J Cardiothorac Vasc Anesth 2011;25(6):981-6.

Mittermayr M, Velik-Salchner C, Stalzer B, et al. Innerhofer. Detection of Protamine and Heparin after Termination of Cardiopulmonary Bypass by Thrombelastometry (ROTEM): Results of a Pilot Study. Anesth Analg 2009;108(3):743-50.

Zmuda K, Neofotistos D, Ts’ao CH. Effects of Unfractionated Heparin, Low-Molecular-Weight Heparin, and Heparinoid on Thromboelastographic Assay of Blood Coagulation. Am J Clin Pathol 2000;113(5):725-31.

Coppella JA, Thalheimerb U, Zambruni A, et al. The effects of unfractionated heparin, low molecular weight heparin and danaparoid on the thromboelastogram (TEG): an in-vitro comparison of standard and heparinasemodified TEGs with conventional coagulation assays. Blood Coagul Fibrinolysis 2006;17(2):97-104.

Uprichard J, Manning RA, Laffan MA. Monitoring heparin anticoagulation in the acute phase response. Br J Haematol 2010;149(4):613-9.

Feuring M, Wehling M, Schultz A. Dalteparin dosedependently increases ROTEM thrombelastography parameters only at supratherapeutic anti-factor Xa levels: An in vitro study. Clin Exp Pharmacol Physiol 2011,38(11):783-6.

MacDonald SG, Luddington RJ. Critical Factors Contributing to the Thromboelastography Trace. Semin Thromb Hemost 2010;36(7):712-22.

Files
IssueVol 53, No 10 (2015) QRcode
SectionOriginal Articles
Keywords
Heparin Anti-Coagulation Coagulability ICU

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Najafi A, Nikeish M, Etezadi F, Pourfakhr P, Imani F, Khajavi MR, Shariat Moharari R. Comparison of aPTT and CT Parameter of the ROTEM Test to Monitor Heparin Anti-Coagulation Effect in ICU Patients: an Observational Study. Acta Med Iran. 2015;53(10):643-646.